Individual hose record

4371506 Hose Repair Specifications

Excavator · Hitachi · EX230LC-5 · Supply and Return Valve

Finished length4,850 mm

Hose repair card

Everything needed to identify and make this hose

Hitachi EX230LC-5Pipe No. 12A · Part 4371506

Make this hose4371506
L = 4,850 mmDN10;1SN-6;7MpaL90°R90°
Finished length4,850 mm
Working pressure7 MPa
Hose specificationDN10;1SN-6;7Mpa
Quantity1
L90°

Left fitting90°美制内螺纹37°内锥JIC 37° · 90°View real fitting photos ↗

R90°

Right fitting90°美制内螺纹37°内锥JIC 37° · 90°View real fitting photos ↗

Route进回油阀~先导滤芯

Tap the card to enlarge it without leaving this page.

4371506 hose repair card

Repair specifications

Part number
4371506
Diagram pipe number
12A
Installation route
进回油阀~先导滤芯
Hose specification
DN10;1SN-6;7Mpa
Finished length
4,850 mm
Working pressure
7 MPa
Left fitting
90°美制内螺纹37°内锥
Right fitting
90°美制内螺纹37°内锥
Quantity
1

Same system

Related Hoses

Diagram Pipe No. 12

9159008

Installation route: 进回油阀~先导滤芯

Length
4,850 mm
Specification
DN10;1SN-6;7Mpa
Left fitting
90°美制内螺纹37°内锥
Right fitting
90°美制内螺纹37°内锥
View full repair specifications

Diagram Pipe No. 13

4365595

Installation route: 进回油阀~中转接头

Length
1,000 mm
Specification
DN10;1SN-6;7Mpa
Left fitting
美制内螺纹37°内锥
Right fitting
90°美制内螺纹37°内锥
View full repair specifications

Workshop guide

Finding the correct hydraulic hose for Hitachi EX230LC-5 Supply and Return Valve

Start with the machine and route

For Hitachi EX230LC-5 Supply and Return Valve, identify the exact model and hydraulic system on the machine first. A part number or diagram pipe number is the fastest way to narrow a replacement hose; if neither is visible, compare the installation route and the existing hose.

See all Hitachi EX230LC-5 systems

Read the dimensions before cutting

Check whether a listed dimension is finished assembly length, hose-only length, or cut length. These are not interchangeable. Confirm hose specification and pressure rating, then compare both ends separately: thread, sealing seat, size, angle, and orientation.

Records to compare

  • 43715064,850 mm · DN10;1SN-6;7Mpa · 进回油阀~先导滤芯

Use the drawing as a location check

Where an installation drawing or manual figure is available, match its callout to the part number and physical route. A hydraulic circuit diagram explains connections but does not show the exact routing of a hose on the machine. Take the old hose or clear end-fitting photographs to the workshop if any dimension is missing.

For reference only. Confirm the actual hose before fabrication.

Scroll to Top