Hose Length and Fitting List

Showing 36 representative records. Return to the finder for a more specific search.

Manual page 3

F689885

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
3,200 mm
Cut length
3,118 mm
Specification
X461LT-12
Left fitting
X10646-12-12
Right fitting
X10646-12-12
View hose specifications

Manual page 1

F046791

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
650 mm
Cut length
590 mm
Specification
X461LT-6
Left fitting
X10646-6-6
Right fitting
X10646-6-6
View hose specifications

Manual page 1

F046347

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
3,400 mm
Cut length
3,330 mm
Specification
X371LT-8
Left fitting
X10670-10-8-SM
Right fitting
X10670-10-8-SM
View hose specifications

Manual page 1

F027328

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,800 mm
Cut length
1,738 mm
Specification
X461LT-4
Left fitting
X10646-6-4
Right fitting
X10646-6-4
View hose specifications

Manual page 2

F075554

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,000 mm
Cut length
939 mm
Specification
X461LT-4
Left fitting
X16846-5-4
Right fitting
X10646-6-4
View hose specifications

Manual page 2

F056626

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,230 mm
Cut length
1,135 mm
Specification
X461LT-12
Left fitting
X13946-12-12
Right fitting
X10646-12-12
View hose specifications

Manual page 1

F046341

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,400 mm
Cut length
1,338 mm
Specification
X461LT-4
Left fitting
X10646-6-4
Right fitting
X10646-6-4
View hose specifications

Manual page 2

F057809

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
800 mm
Cut length
731 mm
Specification
X461LT-6
Left fitting
X13W46-8-6
Right fitting
X16846-8-6
View hose specifications

Manual page 2

F072506

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
550 mm
Cut length
495 mm
Specification
X461LT-4
Left fitting
X10646-6-4
Right fitting
X13W46-4-4
View hose specifications

Manual page 1

F024309

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,200 mm
Cut length
1,142 mm
Specification
X461LT-4
Left fitting
X13946-6-4
Right fitting
X10646-6-4
View hose specifications

Manual page 1

F013333

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
500 mm
Cut length
440 mm
Specification
X461LT-6
Left fitting
X10646-6-6
Right fitting
X10646-6-6
View hose specifications

Manual page 3

F678559

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,530 mm
Cut length
1,359 mm
Specification
XR42-20
Left fitting
XK6AV6-20-20
Right fitting
XK6NV6-24-20
View hose specifications

Manual page 1

F040539

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
3,100 mm
Cut length
3,030 mm
Specification
X371LT-8
Left fitting
X10670-10-8-SM
Right fitting
X10670-10-8-SM
View hose specifications

Manual page 1

F013316

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
770 mm
Cut length
710 mm
Specification
X461LT-6
Left fitting
X10646-6-6
Right fitting
X10646-6-6
View hose specifications

Manual page 2

F074565

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
3,500 mm
Cut length
3,427 mm
Specification
XH31-4
Left fitting
XK39VS-6-4
Right fitting
XK06VS-6-4
View hose specifications

Manual page 2

F062802

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
2,200 mm
Cut length
2,142 mm
Specification
X461LT-4
Left fitting
X13946-6-4
Right fitting
X10646-6-4
View hose specifications

Manual page 3

F681114

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
3,300 mm
Cut length
3,238 mm
Specification
X461LT-4
Left fitting
X10646-6-4
Right fitting
X10646-6-4
View hose specifications

Manual page 1

F013741

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,000 mm
Cut length
936 mm
Specification
X461LT-8
Left fitting
X16846-8-8
Right fitting
X16846-8-8
View hose specifications

Manual page 2

F072551

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,500 mm
Cut length
1,431 mm
Specification
X421SN-8-RED
Left fitting
X13V48-8-8
Right fitting
X16848-8-8
View hose specifications

Manual page 1

F046349

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
3,400 mm
Cut length
3,318 mm
Specification
X371LT-12
Left fitting
X10670-12-12-SM
Right fitting
X10670-12-12-SM
View hose specifications

Manual page 1

F032044

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,010 mm
Cut length
952 mm
Specification
X461LT-4
Left fitting
X13946-6-4
Right fitting
X10646-6-4
View hose specifications

Manual page 2

F065415

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,500 mm
Cut length
1,418 mm
Specification
X371LT-12
Left fitting
X10670-12-12-SM
Right fitting
X10670-12-12-SM
View hose specifications

Manual page 2

F062809

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,500 mm
Cut length
1,434 mm
Specification
X461LT-6
Left fitting
X16846-8-6
Right fitting
X16846-8-6
View hose specifications

Manual page 2

F074872

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
4,300 mm
Cut length
4,165 mm
Specification
X301SN-20
Left fitting
X11948-20-20
Right fitting
X10648-20-20
View hose specifications

Manual page 3

F680953

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
4,400 mm
Cut length
4,290 mm
Specification
X301SN-20
Left fitting
X10648-20-20
Right fitting
X10648-20-20
View hose specifications

Manual page 3

F679611

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,400 mm
Cut length
1,340 mm
Specification
X461LT-4
Left fitting
X16846-4-4
Right fitting
X10646-6-4
View hose specifications

Manual page 1

F027299

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
500 mm
Cut length
423 mm
Specification
X461LT-8
Left fitting
X13W46-10-8
Right fitting
X16846-10-8
View hose specifications

Manual page 2

F064919

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,500 mm
Cut length
1,430 mm
Specification
X371LT-8
Left fitting
X10670-10-8-SM
Right fitting
X10670-10-8-SM
View hose specifications

Manual page 3

F710087

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,700 mm
Cut length
1,628 mm
Specification
X371LT-8
Left fitting
X13970-10-8-SM
Right fitting
X10670-10-8-SM
View hose specifications

Manual page 3

F678560

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,500 mm
Cut length
1,318 mm
Specification
XR42-20
Left fitting
XK6FV6-20-20
Right fitting
XK6AV6-20-20
View hose specifications

Manual page 2

F074769

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,350 mm
Cut length
1,231 mm
Specification
X461LT-16
Left fitting
X11946-20-16
Right fitting
X10646-16-16
View hose specifications

Manual page 3

F694343

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
4,230 mm
Cut length
4,100 mm
Specification
X797TC-12
Left fitting
X13777-12-12
Right fitting
X13777-12-12
View hose specifications

Manual page 1

F010863

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,400 mm
Cut length
1,318 mm
Specification
X371LT-12
Left fitting
X10670-12-12-SM
Right fitting
X10670-12-12-SM
View hose specifications

Manual page 2

F073521

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
3,400 mm
Cut length
3,344 mm
Specification
X371LT-8
Left fitting
X10670-10-8-SM
Right fitting
X10670-12-8-SM
View hose specifications

Manual page 2

F061401

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
1,150 mm
Cut length
1,097 mm
Specification
X461LT-4
Left fitting
X13W46-4-4
Right fitting
X16846-4-4
View hose specifications

Manual page 3

F681108

Application: 1910G Forwarder: Stage V / Tier 4, Fixed Cabin

Length
3,100 mm
Cut length
3,100 mm
Specification
X811-24
Left fitting
X11946-12-12
Right fitting
X10646-12-12
View hose specifications

Machine literature

Related manuals

Use these manuals to identify the machine and compare the hose records below. Available files can be opened here.

Based on current published data

Common Repair Questions

Questions appear only when a published record or linked PDF page provides the answer.

What is the hose length range for John Deere 1910G Forwarder?

Based on published records with valid lengths, the range is 310–6,400 mm. Open the individual record to verify its installation position and both end fittings before fabrication.

Which hose specifications are common for John Deere 1910G Forwarder?

The most frequent raw specifications in the current published records are: X461LT-4 (35 records), X461LT-6 (26 records), X371LT-8 (16 records), X371LT-12 (9 records), X461LT-12 (9 records). Verify the specification together with length, pressure, and fitting details.

How can I identify the left and right hose fittings for John Deere 1910G Forwarder?

Each record keeps the left and right fitting descriptions separate. Current examples: F689885: left X10646-12-12; right X10646-12-12; F046791: left X10646-6-6; right X10646-6-6; F046347: left X10670-10-8-SM; right X10670-10-8-SM. Open the exact part-number or pipe-number record; do not swap ends based on appearance alone.

Optional cross-check

Ask an AI search tool to check this repair data

The question is already written for this machine or hose. Use a tool with web search enabled; treat its answer as a starting point and verify on the machine.

See the exact question being sent
I am checking hydraulic hose repair information for "John Deere 1910G Forwarder Hose Repair Data". Use web search and cite a source for every factual point. Compare this HoseSeek page with manufacturer manuals and reliable parts documentation: https://www.hoseseek.com/machines/john-deere/1910g-forwarder--313931304720466f72776172646572/

Verify, where applicable:
1. Exact machine model and any serial-number range.
2. Hydraulic system and installation route.
3. Hose part number and diagram pipe number.
4. Finished length, hose specification, and pressure rating.
5. Both end fittings, including thread, sealing seat, size, and angle.
6. Installation-diagram position and routing.

State explicitly what you could not verify. Do not infer a missing dimension or fitting. End with a short on-machine checklist for a hose repair technician.
Scroll to Top